Library · Signals, sensing & imaging
What Ultrasonic Imaging & Characterization got wrong, from 41 theses
Summary written by a model from the records below: The records document various technical challenges encountered in ultrasonic imaging, non-destructive testing, and acoustic characterization experiments. Investigators frequently reported failures caused by wave attenuation, acoustic impedance mismatches, resolution limits relative to other modalities, and signal processing artifacts. These records come from graduate theses, 2021 to 2025, each labeled with its degree where the repository states it, and each links to its thesis. They were extracted by language models reading the full text, so treat each as a lead to read, not a verdict.
Plus 10 problems the authors left open, listed at the end.
Failure modes, by theses reporting them
Select a mode to jump to its records.
Severe wave attenuation and scattering obscure acoustic signals across thick or heterogeneous media
High acoustic attenuation, material scattering, and viscous damping obscure wave arrival signatures and severely limit acoustic penetration depth. In addition, wave propagation through skull bone, thick composites, viscous fluids, and deep biological tissues prevents target detection and eliminates high-frequency spatial resolution advantages.
Tried and failed
Ultrasonic pulse transmission for shear-wave arrival detection applied to sediment samples under triaxial loading. Outcome: no signal. Reason: High acoustic attenuation and internal reflections at low effective stress obscured arrival signatures
Evaluating the role of mechanical and hydrologic properties of input sediment to fluid pressure development in the shallow subduction zone · UT Austin · PhD
Tried and failed
ultrasonic guided wave inspection outside optimal frequency-thickness applied to fluid-filled pipes. Outcome: no signal. Reason: frequencies outside 1.0-1.5 MHz-mm caused excessive leaky attenuation of the A0 mode into the fluid
Pipeline health monitoring using helical guided ultrasonic waves · UT Austin · PhD
Tried and failed
ultrasonic C-scan non-destructive testing applied to thick filament-wound composite pipes. Outcome: no signal. Reason: severe acoustic attenuation and scattering in thick filament-wound glass-fiber structures prevented acceptable image clarity
Predicting impact damage in composite structures · Imperial · PhD
Considered and rejected
Considered and rejected: Rejected standard ultrasonic bath immersion due to up to 90% acoustic intensity attenuation through module walls and membrane layers.
Ultrasonic Fouling Mitigation for Renewable Energy Powered Reverse Osmosis Desalination Systems · York University · Master's
Considered and rejected
Considered and rejected: Rejected relying on ultrasound-range (1-3 MHz) acoustic emission sensors for trans-cranial cavitation detection due to severe attenuation (10-30 dB) across the skull.
Cavitation in Blunt Traumatic Brain Injury · Duke · Doctorate
Considered and rejected
Considered and rejected: Rejected Sylgard-184 for ultrasound flow loops due to high acoustic attenuation coefficent
On the extraction of path-dependent dynamics from recirculating pulsatile flows using optical and ultrasound imaging · Queen's University · PhD
Tried and failed
spatial tracking 3D reconstruction from 2D ultrasound applied to calcified vascular lumen volume assessment. Outcome: data insufficient. Reason: acoustic shadowing behind dense calcifications created signal voids that prevented automated volume segmentation
Evaluation of tomographic 3D ultrasound for the assessment of vascular pathology · Imperial · PhD
Considered and rejected
Considered and rejected: Rejected standard ultrasound imaging for in vivo cranial blast cavitation due to poor axial resolution, skull fusion in adult animals, and acoustic backscatter.
Biological cavitation and protein profiles as unique hallmarks of blast-induced traumatic brain injury · Iowa State · PhD
Tried and failed
delay-and-sum ultrasonic imaging applied to thick composite impact damage localization. Outcome: no signal. Reason: weak reflection from small defects combined with guided wave mode dispersion in thick media
Structural health monitoring of thick composites using ultrasonic guided waves · Imperial · PhD
Tried and failed
sensor-tracked freehand 3D ultrasound reconstruction applied to deep tissue vascular imaging. Outcome: no signal. Reason: excessive acoustic penetration depth degraded image quality beyond reconstruction software thresholds
Evaluation of tomographic 3D ultrasound for the assessment of vascular pathology · Imperial · PhD
Tried and failed
high-frequency ultrasound in viscous immersion fluid applied to acoustic reflection resolution enhancement. Outcome: worse than baseline. Reason: Fluid viscous attenuation downshifted the center frequency, eliminating high-frequency spatial resolution advantages.
High-resolution dynamic elastic properties of spatially heterogeneous rocks from measurements of angle-dependent ultrasonic reflection coefficient · UT Austin · PhD
Tried and failed
low-frequency uncontrasted ultrasound Doppler flow measurement applied to in vivo arterial blood flow. Outcome: no signal. Reason: acoustic absorption dominated over blood scattering at frequencies below 15 MHz
Compact modular open platform for low-cost ultrasound imaging · Imperial · PhD
Signal processing and image reconstruction methods introduce artifacts or blur critical features
Discarding phase information or using direct intensity thresholding corrupts ultrasound image reconstruction by blurring speckle patterns and breaking continuous structural contours. Applying unsuitable regularization schemes or filtering algorithms degrades contrast, entangles aberrations across angles, and fails to outperform standard median filtering.
Tried and failed
ultrasonic echo gating using early/late arrivals applied to defect imaging in layered structures. Outcome: no signal. Reason: early echoes lack defect interaction while late echoes suffer from poor signal-to-noise ratio
Ultrasonic guided waves for mechanical defects detection on thin-film solar photovoltaic modules · Georgia Tech · PhD
Tried and failed
1D scanline intensity summation applied to acoustic shadow detection in ultrasound. Outcome: did not generalise. Reason: Oversensitivity from relying on raw pixel intensities instead of dynamic spatial variations
Computer-assisted intraoperative ultrasound in brain tumour surgery · Imperial · PhD
Tried and failed
2D spatial image representation for time-series classification applied to ultrasonic non-destructive testing signal classification. Outcome: worse than baseline. Reason: Synthetic 2D image focusing added computational overhead while yielding poorer classification performance than raw 1D time-domain traces
Machine learning applications in guided wave testing · Imperial · Doctorate
Tried and failed
angular coherence factor on redundant signals applied to ultrasound aberration correction. Outcome: worse than baseline. Reason: local wave aberrations became entangled across angles, lowering contrast compared to standard coherence factor
An Angular Framework for Ultrasound Imaging · EPFL · PhD
Tried and failed
sparse wavelet regularization using iterative shrinkage thresholding applied to ultrasound image reconstruction. Reason: Altered natural speckle patterns and improperly thresholded continuous linear intensity gradients.
Ultrasound Imaging: From Physical Modeling to Deep Learning · EPFL · PhD
Tried and failed
intensity thresholding and adaptive segmentation algorithms applied to speckle-corrupted ultrasound image segmentation. Reason: acoustic speckle noise caused false vessel wall classifications and contour discontinuities
Forward-Viewing Ultrasound Guidance of a Robotically-Steered Guidewire for Peripheral Interventions · Georgia Tech · PhD
Tried and failed
training CNNs on envelope-detected data applied to ultrasound image reconstruction. Outcome: worse than baseline. Reason: envelope detection discards phase information, causing blurred speckle patterns compared to raw RF/IQ representations
Ultrasound Imaging: From Physical Modeling to Deep Learning · EPFL · PhD
Tried and failed
Image deconvolution without geometric aberration correction applied to transcranial ultrasound blood flow imaging. Reason: Disabling cranial aberration coordinate remapping caused systematic vessel diameter underestimation
Ultrasound-based Noninvasive Monitoring Methods for Neurocritical Care · MIT · PhD
Tried and failed
filtered back-projection with ramp filtering applied to plane-wave ultrasound image reconstruction. Outcome: worse than baseline. Reason: missing low-frequency components in transducer Gaussian pulses negated ramp filter benefits
An Angular Framework for Ultrasound Imaging · EPFL · PhD
Acoustic impedance mismatches and defective couplants disrupt sound transmission
Acoustic impedance mismatches across air voids, glass layers, or polymer blocks prevent sound transmission and cause unwanted signal reflections. Furthermore, physical couplant defects such as air bubbles in adhesive layers, thermal degradation of couplants, and mechanical dry clamping degrade signal strength and stability.
Tried and failed
ultrasonic non-destructive testing applied to subsurface biological targets inside internal voids. Outcome: no signal. Reason: acoustic impedance mismatch and signal scattering across air-filled voids prevented target detection
Investigating the infestation : Understanding and communicating Deathwatch beetle activity on HMS Victory · Cranfield · PhD
Tried and failed
ultrasonic C-scan inspection applied to impact-induced kissing bond detection in laminates. Outcome: no signal. Reason: weak interface contact without acoustic impedance mismatch produced no detectable ultrasonic reflection
Low velocity and high velocity impact of composites and fibre metal laminates for commercial aircraft structures · Imperial · PhD
Tried and failed
motor oil acoustic couplant applied to high-temperature ultrasonic guided wave testing. Outcome: no signal. Reason: high ultrasonic wave attenuation and absorption at elevated temperatures
Influence of dynamic load and temperature on guided wave ultrasonic damage detection in thin plates · Cranfield · PhD
Considered and rejected
Considered and rejected: Rejected glass tubes and acrylic blocks due to acoustic impedance mismatch and non-physiological ultrasound representation.
Entwicklung eines kostengünstigen Phantoms für das Erlernen der Dopplersonografie Development of a low-cost phantom for learning Doppler sonography · University of Marburg · PhD
Tried and failed
applying retro-reflective tape for optical detection applied to ultrasonic surface wave measurements. Outcome: worse than baseline. Reason: introduced excessive high-frequency acoustic damping and thickness calibration errors
Texture characterisation in metals using diffuse ultrasound · Imperial · Doctorate
Considered and rejected
Considered and rejected: Rejected glass coverslips for ultrasound imaging due to severe acoustic impedance mismatch (c=5600 m/s, rho=2200 kg/m3) causing total reflection; switched to PDMS coverslips
Ultrasound imaging of cells using gas vesicles and perfluorocarbon nanodroplets · Georgia Tech · PhD
Tried and failed
Viscoelastic couplant for external absorbing boundaries applied to ultrasonic wave absorption. Reason: Large acoustic impedance mismatch and requirement of an unrealistically thin coupling layer.
Ultrasonic methods for assessing fatigue degradation in metals · Imperial · PhD
Tried and failed
elastomer adhesive bonding for acoustic coupling applied to ultrasonic acoustic power transfer interfaces. Outcome: worse than baseline. Reason: adhesive layer introduced bonding defects and trapped air bubbles, degrading acoustic transmission efficiency
Acoustic Power Transfer Leveraging Piezoelectricity and Metamaterials · Georgia Tech · PhD
Tried and failed
dry-coupled mechanical clamping of piezoelectric transducers applied to ultrasonic guided wave structural monitoring. Outcome: worse than baseline. Reason: produced order of magnitude lower voltage amplitude and significantly worse signal stability than adhesive bonding
The use of circumferential guided waves to monitor axial cracks · Imperial · Doctorate
Ultrasonic modalities exhibit inferior spatial resolution and sensitivity compared to competing methods
Standard planar ultrasound and guided wave scans often fail to match the spatial resolution and diagnostic accuracy achieved by competing modalities like radiography, magnetic resonance, and optical coherence tomography. These ultrasonic approaches struggle to resolve fine crack morphology, minor vascular caliber variations, and slow microvascular flow.
Lost to a baseline
Ultrasound detected caliber variations in only 42.77% of cases compared to 82.64% detected by MRCP and 98.68% by ERCP
Sonographische Befunde bei Patienten mit primär sklerosierender Cholangitis · Tübingen · PhD
Lost to a baseline
Radiography showed higher interobserver agreement (Gwet's AC1 0.9215-0.9423) than ultrasound (0.4486).
Ultrasonographic evaluation of sites of osteochondrosis in young Thoroughbred horses · University College Dublin · PhD
Lost to a baseline
For fetal lens visualization, 2D ultrasound outperformed 3D ultrasound across 12–14 weeks (2D achieved 95% vs 3D at 39%).
A prospective three-dimensional imaging and anatomy screening study · Imperial · PhD
Considered and rejected
Considered and rejected: Rejected intravascular ultrasound (IVUS) imaging in favor of optical coherence tomography (OCT) due to resolution limitations (100-120 microns for IVUS vs 10 microns for OCT).
ATHERO52, A Proof of Concept Device Design to Remove and Treat Atherosclerosis with a Non-Invasive Surgical Approach · Harvard · Master's
Lost to a baseline
Conventional ultrasonic C-scan achieves 1 mm x 1 mm spatial resolution, resolving exact crack morphology which Lamb wave scanning cannot.
Ultrasonic guided waves for mechanical defects detection on thin-film solar photovoltaic modules · Georgia Tech · PhD
Tried and failed
two-dimensional ultrasound diameter reduction measurement applied to transplant renal artery stenosis diagnosis. Outcome: worse than baseline. Reason: planar measurements yielded low diagnostic accuracy compared to volumetric and magnetic resonance angiography assessments
The evaluation of advanced ultrasonography applications in the assessment of transplanted kidneys · Imperial · PhD
Tried and failed
conventional colour Doppler ultrasound imaging applied to inter-cord placental vascular anastomoses. Outcome: no signal. Reason: insufficient sensitivity and resolution to detect slow microvascular blood flow between umbilical cords
Placental Vascular imaging and its association with pregnancy outcomes · Imperial · Doctorate
Environmental variations and multipath reverberations distort ultrasonic measurements
Fluctuations in ambient temperature and moisture levels introduce signal shifts that mask or mimic genuine structural damage signatures. Moreover, continuous wave operations and reverberant acoustic propagation paths create standing wave patterns and interference that corrupt boundary profiling.
Tried and failed
linear ultrasonic guided wave damage detection applied to crack detection under varying environmental temperatures. Outcome: no signal. Reason: signal changes from temperature drift masked or mimicked damage-induced acoustic feature changes
Baseline-free structural health monitoring in aeronautical structures under in-service conditions · Imperial · PhD
Considered and rejected
Considered and rejected: Rejected relying solely on ultrasonic signal amplitude/intensity for long-term battery monitoring due to vulnerability to transducer deterioration and temperature fluctuations, choosing relative wave attenuation instead.
Ultrasonic monitoring of temperature distributions and degradation in engineering components · Imperial · PhD
Considered and rejected
Considered and rejected: Rejected active pulse-laser and air-coupled ultrasonic transmitters due to high cost, maintenance difficulty, and acoustic reverberation noise degrading SNR above 2.4 km/h
Development of a new laser doppler vibrometer-based non-contact damage detection system for cracks in rail head · UT Austin · PhD
Transducer geometry flaws, electrical mismatches, and hardware nonlinearities degrade reception
Purely resistive electrical impedance matching causes suboptimal acoustic reflectivity and severe drops in echo-receive efficiency. Transducer element elongation, missing tracking sensors, and system nonlinearities introduce acoustic noise and limit tissue clutter suppression.
Tried and failed
pulse-based phased array wave mixing applied to nonlinear ultrasound characterization of metals. Outcome: no signal. Reason: off-frequency spectral components and lack of precise polarity control prevented harmonic extraction
Nonlinear ultrasound for the characterization of additively manufactured metals · Georgia Tech · PhD
Considered and rejected
Considered and rejected: Single-frequency ultrasound transducers with electronic second-harmonic filtering, rejected due to residual acoustic noise in the signal in favour of pulse inversion / phase-shift harmonic imaging
Evaluation of tomographic 3D ultrasound for the assessment of vascular pathology · Imperial · PhD
Considered and rejected
Considered and rejected: Freehand 3D ultrasound without position sensors, rejected because lack of positional data yields inadequate volumetric reconstruction quality preventing quantitative measurements
Evaluation of tomographic 3D ultrasound for the assessment of vascular pathology · Imperial · PhD
Tried and failed
multipulse harmonic filtering for tissue clutter cancellation applied to row-column array ultrasound imaging. Reason: transducer element elongation and hardware system non-linearities limited suppression to 30-35 dB instead of clinical 50-60 dB
Ultrafast 3-D ultrasound super-resolution imaging with a row-column array · Imperial · PhD
Tried and failed
ultrasonic guided-wave time-of-flight-shift tracking applied to lithium-ion pouch cells. Outcome: no signal. Reason: low signal amplitude and high noise from the specific transducer geometry configuration
Ultrasonic and vibrational methods to determine changes of state of lithium-ion cells · UT Austin · PhD
Tried and failed
purely resistive electrical impedance matching applied to capacitive ultrasound transducer interfaces. Outcome: worse than baseline. Reason: suboptimal acoustic and electrical reflectivity resulted in over 12 dB worse echo-receive efficiency than negative capacitance matching
Integrated Electronics for Wireless Imaging Microsystems with CMUT Arrays · Georgia Tech · PhD
Considered and rejected
Considered and rejected: Rejected lossy backing materials (standard in ultrasound) due to losing up to 50% incident acoustic energy, selecting air backing instead.
Piezoelectric Acoustic Identification Tags with Frequency Multiplexed Energy Harvesting and Backscatter Communication Operation for Underwater Applications · Georgia Tech · PhD
Left open by the authors
Problems the authors named and did not get to.
Left open
Investigate why acoustic power transfer improvement is negligible below 39 kHz when piezoelectric transducer reactance is inductive. Blocker: Requires a physical experimental ultrasonic power transfer testbed with specific piezoelectric transducers (FUS-40E)
Acoustic power distribution techniques for wireless sensor networks · Imperial · Doctorate
Left open
Evaluate guided wave ultrasonic testing parameters for breathing cracks in corroded plate regions under varying temperature conditions. Blocker: Requires experimental ultrasonic testing apparatus (PZT transducers, temperature chamber, corroded/cracked specimens) or complex uncalibrated multi-physics modeling.
Influence of dynamic load and temperature on guided wave ultrasonic damage detection in thin plates · Cranfield · PhD
Left open
Optimize ultrasonic horn dimensions and cross-sectional geometries using acoustic and structural simulations for reverse osmosis fouling mitigation. Blocker: Lack of specific target performance metrics, objective functions, and constraints
Ultrasonic Fouling Mitigation for Renewable Energy Powered Reverse Osmosis Desalination Systems · York University · Master's
Left open
Investigate guided wave ultrasonic damage detection in thin plates under combined dynamic stress and temperature variations. Blocker: Requires a physical testing apparatus with ultrasonic transducers and thermomechanical loading capabilities
Influence of dynamic load and temperature on guided wave ultrasonic damage detection in thin plates · Cranfield · PhD
Left open
Combine ultrasonic backscattering measurements with phase velocity estimates into a unified materials characterisation framework for superalloys. Blocker: Requires ultrasonic physical testing apparatus, transducers, water tank setup, and physical superalloy specimens to perform backscattering measurements.
Phase characterisation of nickel-based superalloys using ultrasound · Imperial · Doctorate
Left open
Develop a method comparing relative ultrasonic guided wave mode amplitudes to characterize defect sizing and orientation. Blocker: Requires ultrasonic phased array hardware, transducer wedges, and experimental defect specimens for validation
Phased array implementation of high frequency, multi-mode dispersion compensation for ultrasonic guided wave inspections · Iowa State · PhD
Left open
Assess whether the ratio of SH0 to axially propagating S0 wave amplitude and phase remains proportional and stable across hardware variations. Blocker: Requires physical ultrasonic transducers, pipe testing apparatus, and hardware variations to measure wave modes.
The use of circumferential guided waves to monitor axial cracks · Imperial · Doctorate
Left open
Correlate measured nonlinear ultrasound beta parameters with material microstructures for selective damage assessment in additively manufactured metals. Blocker: Requires physical experimental ultrasound hardware, wedge transducers, and AM metal samples for microstructure characterization
Nonlinear ultrasound for the characterization of additively manufactured metals · Georgia Tech · PhD
Left open
Identify sources of discrepancy between SRAS and bulk experimental surface acoustic wave velocity measurements in Ti-5Al-5Mo-5V-3Cr samples. Blocker: Requires physical ultrasonic testing equipment, SRAS experimental setup, and specific alloy samples
Ultrasonic characterization of Ti-5Al-5Mo-5V-3Cr · Iowa State · Master's
Left open
Test helical guided ultrasonic waves on liquid-filled, pressurized pipes and examine the effects of coatings, pressure, vibrations, and bends. Blocker: Requires specialized physical experimental setup with pressurized liquid-filled pipes, ultrasonic transducers, and structural testbeds
Pipeline health monitoring using helical guided ultrasonic waves · UT Austin · PhD
Who has worked on this
Authors of the public theses cited on this page, most-cited first.
- Adel Alzahrani · Imperial · PhD · 2022
Evaluation of tomographic 3D ultrasound for the assessment of vascular pathology - Samule Chukwuemeka Olisa · Cranfield · PhD · 2023
Influence of dynamic load and temperature on guided wave ultrasonic damage detection in thin plates - Baptiste Ghislain Emmanuel Hériard-Dubreuil · EPFL · PhD · 2024
An Angular Framework for Ultrasound Imaging - Dicky Januarizky Silitonga · Georgia Tech · PhD · 2023
Ultrasonic guided waves for mechanical defects detection on thin-film solar photovoltaic modules - Aurelio Angelo Bellotti · Georgia Tech · PhD · 2023
Nonlinear ultrasound for the characterization of additively manufactured metals - Euan Craig Rodgers · Imperial · Doctorate · 2023
The use of circumferential guided waves to monitor axial cracks - Liam Horrigan · York University · Master's · 2022
Ultrasonic Fouling Mitigation for Renewable Energy Powered Reverse Osmosis Desalination Systems - Dimitris Perdios · EPFL · PhD · 2021
Ultrasound Imaging: From Physical Modeling to Deep Learning - Melody Ren Xin Png · Imperial · Doctorate · 2025
Texture characterisation in metals using diffuse ultrasound - Yuhang Pan · Imperial · PhD · 2025
Baseline-free structural health monitoring in aeronautical structures under in-service conditions - Alistair Weld · Imperial · PhD · 2025
Computer-assisted intraoperative ultrasound in brain tumour surgery - Ananya Bhardwaj · Georgia Tech · PhD · 2024
Piezoelectric Acoustic Identification Tags with Frequency Multiplexed Energy Harvesting and Backscatter Communication Operation for Underwater Applications
Checking a claim in this area?