What Cyclic Voltammetry (CV) got wrong, from 19 theses

Summary written by a model from the records below: The records document practical limitations and analytical failures encountered when applying cyclic voltammetry across various chemical, material, and sensing systems. Researchers frequently faced challenges including overlapping background reactions, solvent stability limits, capacitive and ohmic distortions, matrix interferences, and mass transport or kinetic complexities that impeded accurate characterization. These records come from graduate theses, 2021 to 2025, each labeled with its degree where the repository states it, and each links to its thesis. They were extracted by language models reading the full text, so treat each as a lead to read, not a verdict.

19
theses
13
institutions
21
failure records
5
failure modes

Plus 9 problems the authors left open, listed at the end.

Failure modes, by theses reporting them

Select a mode to jump to its records.

Confounding kinetics and mass transport limitations impede quantitative analysis and parameter extraction
6
6 theses · 4 institutions · 6 records
Weak electrochemical signals are swamped by parasitic reactions and background currents
3
3 theses · 3 institutions · 4 records
Capacitive charging currents and uncompensated ohmic drop distort voltammetric measurements
4
4 theses · 4 institutions · 4 records
Target redox processes fall outside the electrochemical stability window of the solvent or electrolyte
3
3 theses · 3 institutions · 3 records
Complex media and solvent interactions introduce peak artifacts, broadening, and potential shifts
3
3 theses · 3 institutions · 4 records

Confounding kinetics and mass transport limitations impede quantitative analysis and parameter extraction

6 theses · 4 institutions

High scan rates, bulk intercalation processes, and reverse scan distortions prevented accurate determination of intrinsic catalytic activity and degradation behavior. Additionally, narrow overpotential ranges and competing reaction kinetics prevented the reliable extraction of standard potentials, transfer coefficients, and dissociation parameters.

Tried and failed

direct cyclic voltammetry on sensing electrode applied to standard reduction potential determination. Outcome: data insufficient. Reason: could not acquire standard potential with sufficient precision under experimental conditions

Diagnosing Band-Mediated Electrochemical Half-Reaction Mechanisms and Identifying the Unique Features Thereof · MIT · PhD

Tried and failed

variable scan rate cyclic voltammetry trumpet plots applied to interfacial electron transfer kinetic parameter extraction. Outcome: data insufficient. Reason: limited overpotential perturbation ranges prevented reliable extraction of transfer coefficients

Mechanistic Studies of Interfacial Proton-Coupled Electron Transfer to Molecularly Defined Surface Sites · MIT · PhD

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (20 mV/s) for liquid cell degradation studies because high scan rate causes mass transport limitations and peak broadening, failing to match galvanostatic battery degradation

Towards reproducible lithium-ion battery cycling using liquid-phase transmission electron microscopy · EPFL · PhD

Considered and rejected

Considered and rejected: Rejected using fast cyclic voltammetry for quantifying intrinsic OER activity on oxygen-deficient perovskites because currents from bulk electrochemical oxygen intercalation overestimate catalytic activity; used steady-state galvanostatic measurements instead.

Activity and Stability Design Principles of Transition Metal Compounds for Decarbonization · MIT · PhD

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) in favor of linear sweep voltammetry (LSV) for soluble-insoluble systems (Ni/Cr) due to distortions from reverse scans.

Rotating Disk Electrode Design for Concentration Measurements in Flowing Molten Chloride Salts · Virginia Tech · Master's

Considered and rejected

Considered and rejected: Rejected full cyclic voltammetric wave analysis (peak potential/current) for extracting acetic acid dissociation parameters in favor of steady-state limiting current analysis at a microelectrode to avoid requiring unknown hydrogen evolution reaction kinetics/mechanisms on Pt electrodes.

Computational electrochemistry · Oxford · PhD

Weak electrochemical signals are swamped by parasitic reactions and background currents

3 theses · 3 institutions

Low analyte concentrations and sub-picoampere electrochemical currents were frequently obscured by dominant electrolyte background reactions. Furthermore, overlapping background processes and spurious gas evolution from surface contamination prevented the detection of target redox peaks and desorption signals.

Tried and failed

cyclic voltammetry applied to organic ligand redox characterization. Outcome: no signal. Reason: redox currents were undetectable due to overlapping background processes

Synthesis and characterisation of conductive metal-organic framework materials · Oxford · PhD

Tried and failed

cyclic voltammetry applied to atomically thin 2D heterostructures. Outcome: no signal. Reason: Sub-picoampere electrochemical currents were dominated and obscured by parasitic electrolyte background reactions

The Physics of High-Temperature Superconducting Cuprates in van der Waals Heterostructures · Harvard · PhD

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry for monitoring intercalation because sub-picoampere currents were swamped by parasitic electrolyte reactions, choosing in-situ Hall potentiometry instead

The Physics of High-Temperature Superconducting Cuprates in van der Waals Heterostructures · Harvard · PhD

Tried and failed

in situ liquid-cell cyclic voltammetry applied to uncleaned nanoparticle-modified microelectrodes. Outcome: no signal. Reason: surface contamination caused spurious gas evolution obscuring characteristic electrochemical redox peaks

In situ electron microscopy of nanomaterials dynamics in heterogeneous phase environments · MIT · PhD

Capacitive charging currents and uncompensated ohmic drop distort voltammetric measurements

4 theses · 4 institutions

Large non-Faradaic capacitive currents and uncompensated resistance drops degraded measurement accuracy and caused classification models to fail at fast scan rates. Uncorrectable iR drop distortions and ohmic sensitivity also prevented the reliable extraction of standard electrochemical potentials and electron transfer rate constants.

Tried and failed

physics-informed Bayesian model hypothesis testing applied to electrochemical cyclic voltammetry classification. Outcome: did not generalise. Reason: kinetic limitations, uncompensated resistance drop, and unmodeled capacitive charging currents at faster scan rates

Voltammetric Methods Augmented with Physical Models and Statistical Inference · MIT · PhD

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) and linear sweep voltammetry (LSV) for electrode current-potential characterization due to large capacitive currents; multistep chronoamperometry was selected instead.

Novel electrode fabrication and reactor design for electrocatalytic nitrate and nitrite reduction in drinking water treatment · UT Austin · PhD

Considered and rejected

Considered and rejected: Rejected onset potentials in voltammetry for calculating standard electrochemical potentials because onset potentials are poorly defined and sensitive to temperature and ohmic currents.

Sulfones and side chains: structure-function-performance relationships in linear conjugated polymer photocatalysts for the evolution of hydrogen from water · Imperial · PhD

Considered and rejected

Considered and rejected: Rejected extracting ET rate constants at high overpotentials via fast-scan cyclic voltammetry (Laviron method) due to uncorrectable iR drop distortion and potential SAM oxidative desorption.

Infrared Spectroelectrochemical Studies of Redox-Active Self Assembled Monolayers: Structure and Kinetics · Saskatchewan · PhD

Target redox processes fall outside the electrochemical stability window of the solvent or electrolyte

3 theses · 3 institutions

Target molecules and coordination complexes frequently failed to display measurable redox activity because their redox couples fell outside the accessible solvent window. Similarly, high electron affinities or aqueous electrolyte boundaries precluded the observation of reversible redox responses for polymers and capping ligands.

Tried and failed

electrochemical reduction characterization via cyclic voltammetry applied to uranyl Schiff base coordination complexes. Outcome: no signal. Reason: redox couples fell outside the electrochemical solvent potential window

Synthesis and Characterization of Acyclic Schiff Bases and Redox Active Chelation of Actinides · Texas Tech · PhD

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) for HOMO determination in Chapter II because many BBOs did not exhibit a redox cycle within the solvent window, using UPS instead.

The evolution of linear and cross-conjugated benzobisoxazole organic semiconductors designed for organic light-emitting diode application · Boston University · PhD

Tried and failed

electrochemical cyclic voltammetry in aqueous electrolyte applied to conjugated copolymer with high electron affinity. Outcome: no signal. Reason: electron affinity was too high to permit redox response in aqueous solution

Design, Synthesis, and Characterization of Electron Transporting DPP-based Copolymers for Application in Organic Electronics · Georgia Tech · PhD

Complex media and solvent interactions introduce peak artifacts, broadening, and potential shifts

3 theses · 3 institutions

Biological media and buffers caused significant peak broadening, oxidative current attenuation, and large negative switching artifacts at high potentials. In addition, polar solvents altered energy levels upon contact with films, while oxidized catalyst forms and ligands produced confounding extraneous peaks.

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) for measuring dye frontier orbitals because polar electrolyte solvents altered energy levels upon contact with thin films

Bridging the gap between stability and performance of next-generation light-converting materials · University of Washington · PhD

Considered and rejected

Considered and rejected: Rejected measuring catalyst cyclic voltammetry redox potentials due to excessive unknown peaks from oxidized catalyst forms and ligands.

Anti- Bacterial Properties Of Bisphenolic Honokiol Derivatives · Penn · PhD

Tried and failed

Fast scan cyclic voltammetry at high potentials applied to analyte detection in HEPES buffer. Reason: Buffer introduced a large negative switching peak artifact when scanning up to high anodic potential.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial · PhD

Tried and failed

Fast scan cyclic voltammetry at microelectrodes applied to analyte detection in cell culture media. Outcome: no signal. Reason: Complex media components caused severe peak broadening, positive potential shifts, and attenuated oxidative current.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial · PhD

Left open by the authors

Problems the authors named and did not get to.

Left open

Test pCOOH-DPPTz-BTh films via cyclic voltammetry in aqueous electrolyte to assess electrochemical stability and measure OECT device performance. Blocker: Requires synthesized polymer samples and physical wet lab electrochemical/transistor testing apparatus.

Design, Synthesis, and Characterization of Electron Transporting DPP-based Copolymers for Application in Organic Electronics · Georgia Tech · PhD

Left open

Resolve the discrepancy in current peak magnitudes between cyclic voltammetry and differential pulse voltammetry measurements during oligomer degradation. Blocker: Requires wet lab electrochemical experiments (CV and DPV) and physical samples undergoing oligomer degradation.

Thin-film transistor : characterization, scaling studies, and applications in electrochemical charge sensing · UT Austin · PhD

Left open

Elucidate mechanistic pathways and obtain cyclic voltammetry profiles for direct and NaCl-mediated electrochemical oxidations of amines. Blocker: Requires wet-lab electrochemical equipment and cyclic voltammetry experiments

An Electrochemical Oxidation Prins-type Cyclisation Sequence for the Synthesis of Substituted N-Heterocycles and Copper-Catalyzed Conjugate Addition Towards Hydnocarpic Acid Synthe · University College Dublin · PhD

Left open

Investigate low-potential current density increases observed during cyclic voltammetry of P(EO-MO) electrolytes with LiTFSI. Blocker: Requires a wet lab with polymer synthesis capabilities and electrochemical cyclic voltammetry equipment.

Developing Dynamic Plastics for Improved Sustainability and Energy Storage Technologies · Cornell · PhD

Left open

Perform cyclic voltammetry on 5,6,9,10-tetramethoxy-2-methylphenanthro[9,10-b]thiophene to determine the mechanism of the second oxidative annulation. Blocker: Requires wet lab electrochemistry equipment and synthesized chemical intermediate (5,6,9,10-tetramethoxy-2-methylphenanthro[9,10-b]thiophene).

Part 1: Structure-Property Relationships of Regioregular Poly(3-alkylthiophene)s Bearing Branched Side Chains Part 2: Ferric Chloride-Promoted Oxidative Annulation of 3,3’,4,4’-Tet · Georgia Tech · PhD

Left open

Identify and test negative electrolytes with redox potentials between -0.3 V and -0.6 V for acidic Fe-QA redox flow batteries. Blocker: Requires wet chemistry lab, chemical synthesis, and electrochemical full-cell testing hardware

Development of Iron Complex-based Aqueous Redox Flow Batteries for Large-scale Energy Storage · Harvard · PhD

Left open

Characterize square wave voltammetry on bipolar electrodes to background-subtract capacitive charging current. Blocker: Requires a physical electrochemical wet lab and bipolar electrode apparatus

Development of electrochemical and electrokinetic methods to improve the sensitivity of diagnostic devices: 1) periodic voltammetry on bipolar electrodes and 2) electrokinetic enri · Iowa State · PhD

Left open

Develop deconvolution or Fickian diffusion models to separate overlapping secondary insulin and serotonin oxidation peaks from fast-scan cyclic voltammograms. Blocker: Requires experimental FSCV voltammogram datasets from bevelled carbon fiber microelectrodes or wet lab electrochemistry equipment.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial · PhD

Left open

Develop statistical variance models for voltammetric current measurements incorporating baseline drift and capacitive effects. Blocker: Requires experimental voltammetry data with known ground-truth noise profiles or a wet lab to collect calibration datasets

Voltammetric Methods Augmented with Physical Models and Statistical Inference · MIT · PhD

Who has worked on this

Authors of the public theses cited on this page, most-cited first.

Checking a claim in this area?

We can run the same search on any method or claim. If nothing turns up, we will say so, and that proves nothing on its own.